Differential thermal overload relays for using with fuse |
Compensated relays with manual or automatic rest, with ralay trip indicator, for AC, or DC. |
Relay setting range |
|
For using with contactor LC2- |
Reference |
Weight |
aM |
gG |
BS88 |
A |
A |
A |
A |
|
|
|
Class 10A(1) with connection by screw clamp teminals |
0.10...0.16 |
0.25 |
2 |
- |
D09...D38 |
YLRD-01 |
0.124 |
0.16...0.25 |
0.5 |
2 |
- |
D09...D38 |
YLRD-02 |
0.124 |
0.25...0.40 |
1 |
2 |
- |
D09...D38 |
YLRD-03 |
0.124 |
0.40...0.63 |
1 |
2 |
- |
D09...D38 |
YLRD-04 |
0.124 |
0.63...1 |
2 |
4 |
- |
D09...D38 |
YLRD-05 |
0.124 |
10001.7 |
2 |
4 |
6 |
D09...D38 |
YLRD-06 |
0.124 |
1.6...2.5 |
4 |
6 |
10 |
D09...D38 |
YLRD-07 |
0.124 |
2.5...4 |
6 |
10 |
16 |
D09...D38 |
YLRD-08 |
0.124 |
4...6 |
8 |
16 |
16 |
D09...D38 |
YLRD-10 |
0.124 |
5.5...8 |
12 |
20 |
20 |
D09...D38 |
YLRD-12 |
0.124 |
7...10 |
12 |
20 |
20 |
D09...D38 |
YLRD-14 |
0.124 |
9...13 |
16 |
25 |
25 |
D12...D38 |
YLRD-16 |
0.124 |
12...18 |
20 |
35 |
32 |
D18...D38 |
YLRD-21 |
0.124 |
16...24 |
25 |
50 |
50 |
D25...D38 |
YLRD-22 |
0.124 |
23...32 |
40 |
63 |
63 |
D25...D38 |
YLRD-32 |
0.124 |
30...38 |
50 |
80 |
80 |
D32 and D38 |
YLRD-35 |
0.124 |
17...25 |
25 |
50 |
50 |
D40...D95 |
YLRD-3322 |
0.510 |
23...32 |
40 |
63 |
63 |
D40...D95 |
YLRD-3353 |
0.510 |
30...40 |
40 |
100 |
80 |
D40...D95 |
YLRD-3355 |
0.510 |
37...50 |
63 |
100 |
100 |
D40...D95 |
YLRD-3357 |
0.510 |
48...65 |
63 |
100 |
100 |
D50...D95 |
YLRD-3359 |
0.510 |
55...70 |
80 |
125 |
125 |
D50...D95 |
YLRD-3361 |
0.510 |
63...80 |
80 |
125 |
125 |
D65 and D96 |
YLRD-3363 |
0.510 |
80...104 |
100 |
160 |
160 |
D80 and D95 |
YLRD-3365 |
0.510 |
80...104 |
125 |
200 |
160 |
D115 and D150 |
YLRD-4365 |
0.900 |
95...120 |
125 |
200 |
200 |
D115 and D150 |
YLRD-4367 |
0.900 |
110...140 |
160 |
250 |
200 |
D150 |
YLRD-4369 |
0.900 |
80...104 |
100 |
160 |
160 |
(2) |
YLRD-33656 |
1.000 |
95...120 |
125 |
200 |
200 |
(2) |
YLRD-33676 |
1.000 |
110...140 |
160 |
250 |
200 |
(2) |
YLRD-33696 |
1.000 |
Class 10A(1)with spring terminal connections(for direct mounting on the contactor only) |
0.10...0.16 |
0.25 |
2 |
- |
D09...D38 |
YLRD-013 |
0.140 |
0.16...0.25 |
0.5 |
2 |
- |
D09...D38 |
YLRD-023 |
0.140 |
0.25...0.40 |
1 |
2 |
- |
D09...D38 |
YLRD-033 |
0.140 |
0.40...0.63 |
1 |
2 |
- |
D09...D38 |
YLRD-043 |
0.140 |
0.63...1 |
2 |
4 |
- |
D09...D38 |
YLRD-053 |
0.140 |
1...1.6 |
2 |
4 |
6 |
D09...D38 |
YLRD-063 |
0.140 |
1.6...2.5 |
4 |
6 |
10 |
D09...D38 |
YLRD-073 |
0.140 |
2.5...4 |
6 |
10 |
16 |
D09...D38 |
YLRD-083 |
0.140 |
4...6 |
8 |
16 |
16 |
D09...D38 |
YLRD-103 |
0.140 |
5.5...8 |
12 |
20 |
20 |
D09...D38 |
YLRD-123 |
0.140 |
7...10 |
12 |
20 |
20 |
D09...D38 |
YLRD-143 |
0.140 |
9...13 |
16 |
25 |
25 |
D12...D38 |
YLRD-163 |
0.140 |
12...18 |
20 |
32 |
32 |
D18...D38 |
YLRD-213 |
0.140 |
16...24 |
25 |
50 |
50 |
D25...D38 |
YLRD-223 |
0.140 |
Thermal overload relays for using with unbalanced loads |
Class 10A(1) with connection by screw clamp terminals |
Change the prefix in the references above from LRD(except LRD-4...)to LR3-D |
Exaple:LRD-01 becomes LR3-D01 |
Termal overload relays for using on 1000V supplies |
Class 10A(1) with connection by screw clamp terminals |
(1) Standard IEC947-1 specifies a tripping time for 7.2 times the setting current IR;class 10A; between 2 and seconds.
(2)Independent mounting |